Felicity Solar IVPM Low Frequency Solar Inverter With 120A MPPT Solar Inverter , Long Life span, Digital Screen and Stronger Protection. Solar inverter, or converter, or PV inverter converts the variable DC output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC) that can be off-grid electrical network. It is a critical balance of system–component in a solar power system, allowing the use of ordinary AC-powered equipment
IVPM Inverter SPECIFICATIONS
Model | IVPM2512 | IVPM2524 | IVPM3524 | IVPM3548 | IVPM5024 | IVPM5048 | IVPM7548 | IVPM10048 |
Rated Output Power(VA) | 2500VA | 2500VA | 3500VA | 3500VA | 5000VA | 5000VA | 7500VA | 10000VA |
Rated Output Power(W) | 2000W | 2000W | 2800W | 2800W | 4000W | 4000W | 6000W | 8000W |
Nominal DC Input Voltage | 12V | 24V | 48V | 24V | 48V |
Input Voltage Waveform | Sinusoidal(Utility or generator) |
Nominal Input Voltage | 220Vac |
Low Line Disconnect | 170±7Vac(UPS) 90±7Vac(APL) |
Low Line Re-connect AC Input Range | 180±7Vac(UPS) 100±7Vac(APL) |
High Line Disconnect | 280±7Vac |
High Line Re-connect | 270±7Vac |
Max AC Input Voltage | 280Vrms |
Nominal Input Frequency | 50Hz/60Hz |
Low Line Frequency Disconnect | 40±1Hz |
Low Line Frequency Re-connect | 42±1Hz |
High Line Frequency Disconnect | 65±1Hz |
High Line Frequency Re-connect | 63±1Hz |
Output Voltage Waveform | As same as input waveform |
Over-Load Protection(SMPS load) | AC 30A | Air switch protection |
Output Short Circuit Protection | AC 30A | Air switch protection |
Efficiency(Line mode) | ≥95% (Rated R load, and battery is fully charged) |
Transfer Time (AC to DC) | 15ms (typical) |
Transfer Time(DC toAC) | 15ms (typical) |
Pass Through Without Battery | No |
Max Bypass Overload Current | AC 30A | AC 63A |
Utility Charge Mode Specifications |
Nominal Input Voltage | 220Vac |
Input Voltage Range | 90~280Vac |
Nominal Output Voltage | Dependent on battery type |
Max Charge Current | 40A | 50A | 60A | 80A |
Charge Current Regulation | 0A~40A | 0A~50A | 0A~60A | 0A~80A |
Battery Initial Voltage | Circuit breaker |
Charger Short Circuit | AC30A | AC 63A |
Breaker Size | Dependent on battery type or Self-defined |
Over Charge Protection | Yes |
Technical Details
Model number: |
IVPM10048 |
Part Number: |
IVPM10048 |
Seller SKU: |
0104 |
Condition: |
New
|
Manufacturer: |
Felicity Solar |
Origin: |
China |
Availability: |
In Stock |
Minimum order quantity: |
1 |
Date first listed on Axume
:
|
Dec 5, 2024 |
IVPM Inverter SPECIFICATIONS
Model | IVPM2512 | IVPM2524 | IVPM3524 | IVPM3548 | IVPM5024 | IVPM5048 | IVPM7548 | IVPM10048 |
Rated Output Power(VA) | 2500VA | 2500VA | 3500VA | 3500VA | 5000VA | 5000VA | 7500VA | 10000VA |
Rated Output Power(W) | 2000W | 2000W | 2800W | 2800W | 4000W | 4000W | 6000W | 8000W |
Nominal DC Input Voltage | 12V | 24V | 48V | 24V | 48V |
Input Voltage Waveform | Sinusoidal(Utility or generator) |
Nominal Input Voltage | 220Vac |
Low Line Disconnect | 170±7Vac(UPS) 90±7Vac(APL) |
Low Line Re-connect AC Input Range | 180±7Vac(UPS) 100±7Vac(APL) |
High Line Disconnect | 280±7Vac |
High Line Re-connect | 270±7Vac |
Max AC Input Voltage | 280Vrms |
Nominal Input Frequency | 50Hz/60Hz |
Low Line Frequency Disconnect | 40±1Hz |
Low Line Frequency Re-connect | 42±1Hz |
High Line Frequency Disconnect | 65±1Hz |
High Line Frequency Re-connect | 63±1Hz |
Output Voltage Waveform | As same as input waveform |
Over-Load Protection(SMPS load) | AC 30A | Air switch protection |
Output Short Circuit Protection | AC 30A | Air switch protection |
Efficiency(Line mode) | ≥95% (Rated R load, and battery is fully charged) |
Transfer Time (AC to DC) | 15ms (typical) |
Transfer Time(DC toAC) | 15ms (typical) |
Pass Through Without Battery | No |
Max Bypass Overload Current | AC 30A | AC 63A |
Utility Charge Mode Specifications |
Nominal Input Voltage | 220Vac |
Input Voltage Range | 90~280Vac |
Nominal Output Voltage | Dependent on battery type |
Max Charge Current | 40A | 50A | 60A | 80A |
Charge Current Regulation | 0A~40A | 0A~50A | 0A~60A | 0A~80A |
Battery Initial Voltage | Circuit breaker |
Charger Short Circuit | AC30A | AC 63A |
Breaker Size | Dependent on battery type or Self-defined |
Over Charge Protection | Yes |