TECHNICAL SPECIFICATIONS | R6 SWING |
---|
| Input voltage | 90V - 240V AC 1 |
| Motor voltage | 12V DC |
| Current Consumption (mains) | |
| CP13E | 80mA (90V - 240V AC +/-10% @ 50Hz1) |
| CP84SM | 170mA (90V - 240V AC +/-10% @ 50Hz1) |
| Maximum DC Current Draw | 16A |
| Maximum Output Torque | |
| Standard-torque operator | 300Nm |
| High-torque operator | 390Nm |
| Power Supply3 | |
| Domestic | 0.8A CP13E, 7.2Ah Battery |
| Light-industrial | 1.8A CP84SM, 7.2Ah Battery |
| Industrial | 1.8A CP84SM, 33Ah Battery |
| Maximum Daily Operations | Mains present | | Back-up2 | |
---|
| | Double Leaf | Single Leaf | Double Leaf | Single Leaf |
| Domestic | 20 | 30 | 20 | 30 |
| Light-industrial | 250 | 250 | 40 | 60 |
| Industrial | 250 | 250 | 250 | 250 |
| Maximum Daily Continuous Operations | Mains present | Mains present |
---|
| | Double leaf | Single leaf |
| Domestic | 20 | 30 |
| Light-industrial | 50 | 50 |
| Industrial | 100 | 100 |
| SPECIFICATIONS CONTINUE | |
---|
| Typical Gate Operating Time: Standard-torque operator / High-torque operator | 12s / 15s |
| Mass of Motor Kit4 (excluding pedestal or wall bracket) | 15kg |
| Collision Sensitivity | Electronic - Adjustable |
| Temperature Range | -15°C to +50°C |
| Housing Protection | IP55 |
1: R6 Swing gate motor can operate off a solar supply, please consult Centurion Systems (Pty) Ltd for assistance.
2: These values are based on fully charged batteries, derate accordingly based on connected ancillaries.
3: Choose appropriate variation based on site requirements.
4: The weight of an operator kit (regardless of Master or Slave).
GATE SPECIFICATIONS
R6 Standard-Torque Operator
| | | | | | | | | |
---|
| Gate Length (m) | 1.5 | 2 | 2.5 | 32 | 3.52 | 42 | 4.52 | 52 |
| Gate Height (m) | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 |
| Max Mass (Kg) | 500 | 500 | 480 | 330 | 240 | 185 | 145 | 120 |
| Allowable Wind Speed For 25% Clad (Km/h)1 | 114 | 84.7 | 67.3 | 56.9 | 49.2 | 43.2 | 38.6 | 34.8 |
| Allowable Wind Speed For 100% Clad (Km/h)1 | 57 | 42.4 | 33.6 | 28.5 | 24.6 | 21.6 | 19.3 | 17.4 |
1: No wind opening time ~ 12s. Gate opening and closing times will increase as wind speed increases.
2: Fit an electric gate lock if the leaf width is greater than 3 metres.
R6 High-Torque Operator
| | | | | | | | | |
---|
| Gate Length (m) | 1.5 | 2 | 2.5 | 32 | 3.52 | 42 | 4.52 | 52 |
| Gate Height (m) | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 |
| Max Mass (Kg) | 750 | 750 | 620 | 430 | 315 | 240 | 190 | 155 |
| Allowable Wind Speed For 25% Clad (Km/h)1 | 128.4 | 95 | 76.3 | 64.6 | 55.9 | 49.2 | 43.9 | 39.6 |
| Allowable Wind Speed For 100% Clad (Km/h)1 | 64.2 | 47.5 | 38.1 | 32.3 | 27.9 | 24.6 | 21.9 | 19.8 |
1: No wind opening time ~ 15s. Gate opening and closing times will increase as wind speed increases.
2: Fit an electric gate lock if the leaf width is greater than 3 metres.