TECHNICAL SPECIFICATIONSR6 SWING
Input voltage90V - 240V AC 1
Motor voltage12V DC
Current Consumption (mains)
CP13E80mA (90V - 240V AC +/-10% @ 50Hz1)
CP84SM170mA (90V - 240V AC +/-10% @ 50Hz1)
Maximum DC Current Draw16A
Maximum Output Torque
Standard-torque operator300Nm
High-torque operator390Nm
Power Supply3
Domestic0.8A CP13E, 7.2Ah Battery
Light-industrial1.8A CP84SM, 7.2Ah Battery
Industrial1.8A CP84SM, 33Ah Battery

Maximum Daily OperationsMains presentBack-up2
Double LeafSingle LeafDouble LeafSingle Leaf
Domestic20302030
Light-industrial2502504060
Industrial250250250250

Maximum Daily Continuous OperationsMains presentMains present
Double leafSingle leaf
Domestic2030
Light-industrial5050
Industrial100100

SPECIFICATIONS CONTINUE
Typical Gate Operating Time: Standard-torque operator / High-torque operator12s / 15s
Mass of Motor Kit4 (excluding pedestal or wall bracket)15kg
Collision SensitivityElectronic - Adjustable
Temperature Range-15°C to +50°C
Housing ProtectionIP55

1: R6 Swing gate motor can operate off a solar supply, please consult Centurion Systems (Pty) Ltd for assistance.
2: These values are based on fully charged batteries, derate accordingly based on connected ancillaries.
3: Choose appropriate variation based on site requirements.
4: The weight of an operator kit (regardless of Master or Slave).

GATE SPECIFICATIONS

R6 Standard-Torque Operator

Gate Length (m)1.522.5323.52424.5252
Gate Height (m)1.81.81.81.81.81.81.81.8
Max Mass (Kg)500500480330240185145120
Allowable Wind Speed For 25% Clad (Km/h)111484.767.356.949.243.238.634.8
Allowable Wind Speed For 100% Clad (Km/h)15742.433.628.524.621.619.317.4

1: No wind opening time ~ 12s. Gate opening and closing times will increase as wind speed increases.
2: Fit an electric gate lock if the leaf width is greater than 3 metres.

R6 High-Torque Operator

Gate Length (m)1.522.5323.52424.5252
Gate Height (m)1.81.81.81.81.81.81.81.8
Max Mass (Kg)750750620430315240190155
Allowable Wind Speed For 25% Clad (Km/h)1128.49576.364.655.949.243.939.6
Allowable Wind Speed For 100% Clad (Km/h)164.247.538.132.327.924.621.919.8

1: No wind opening time ~ 15s. Gate opening and closing times will increase as wind speed increases.
2: Fit an electric gate lock if the leaf width is greater than 3 metres.


Technical Details

Seller SKU: D30
Condition: New
Manufacturer: Centurion
Availability: In Stock
Minimum order quantity: 1
Date first listed on Axume : Jan 7, 2025
TECHNICAL SPECIFICATIONSR6 SWING
Input voltage90V - 240V AC 1
Motor voltage12V DC
Current Consumption (mains)
CP13E80mA (90V - 240V AC +/-10% @ 50Hz1)
CP84SM170mA (90V - 240V AC +/-10% @ 50Hz1)
Maximum DC Current Draw16A
Maximum Output Torque
Standard-torque operator300Nm
High-torque operator390Nm
Power Supply3
Domestic0.8A CP13E, 7.2Ah Battery
Light-industrial1.8A CP84SM, 7.2Ah Battery
Industrial1.8A CP84SM, 33Ah Battery

Maximum Daily OperationsMains presentBack-up2
Double LeafSingle LeafDouble LeafSingle Leaf
Domestic20302030
Light-industrial2502504060
Industrial250250250250

Maximum Daily Continuous OperationsMains presentMains present
Double leafSingle leaf
Domestic2030
Light-industrial5050
Industrial100100

SPECIFICATIONS CONTINUE
Typical Gate Operating Time: Standard-torque operator / High-torque operator12s / 15s
Mass of Motor Kit4 (excluding pedestal or wall bracket)15kg
Collision SensitivityElectronic - Adjustable
Temperature Range-15°C to +50°C
Housing ProtectionIP55

1: R6 Swing gate motor can operate off a solar supply, please consult Centurion Systems (Pty) Ltd for assistance.
2: These values are based on fully charged batteries, derate accordingly based on connected ancillaries.
3: Choose appropriate variation based on site requirements.
4: The weight of an operator kit (regardless of Master or Slave).

GATE SPECIFICATIONS

R6 Standard-Torque Operator

Gate Length (m)1.522.5323.52424.5252
Gate Height (m)1.81.81.81.81.81.81.81.8
Max Mass (Kg)500500480330240185145120
Allowable Wind Speed For 25% Clad (Km/h)111484.767.356.949.243.238.634.8
Allowable Wind Speed For 100% Clad (Km/h)15742.433.628.524.621.619.317.4

1: No wind opening time ~ 12s. Gate opening and closing times will increase as wind speed increases.
2: Fit an electric gate lock if the leaf width is greater than 3 metres.

R6 High-Torque Operator

Gate Length (m)1.522.5323.52424.5252
Gate Height (m)1.81.81.81.81.81.81.81.8
Max Mass (Kg)750750620430315240190155
Allowable Wind Speed For 25% Clad (Km/h)1128.49576.364.655.949.243.939.6
Allowable Wind Speed For 100% Clad (Km/h)164.247.538.132.327.924.621.919.8

1: No wind opening time ~ 15s. Gate opening and closing times will increase as wind speed increases.
2: Fit an electric gate lock if the leaf width is greater than 3 metres.

No reviews

busy...

We use cookies to improve user experience, and analyze website traffic. For these reasons, we may share your site usage data with our analytics partners. By continuing to the site, you consent to store on your device all the technologies described in our cookie policy. Here is the the cookie policy